Get A Quote
  1. Home
  2. >News
  3. > What is the reason why the small motor of the crusher does not rotate

What is the reason why the small motor of the crusher does not rotate

Dec 10 2019 The output does not meet the factory standards Cause analysis 1 The hardness or toughness of the material to be crushed exceeds the range specified in the instruction manual 2 The motor wiring position is reversed and the movable jaw rotates clockwise or the motor should have been connected in a delta connection but a star connection

Get Price
Get In Touch

You can also send a message to us by this email [email protected], we will reply tu you within 24 hours.Now tell us your need,there will be more favorable prices!

Product Introduction

Common Causes for Electric Motor Failure Motor

Jul 21 2010 Most of them are caused by the overheating of motor There are also other factors which greatly affect the performance of electric motors such as low resistance dirt moisture overcurrent and vibrations Electric motors should be installed very carefully and should be

The reason is to find partly in the variation of the mineral crystals compounds hardsoft abrasive non abrasive partly in the design and performance of the equipment Size control is the

Mar 05 2008 Mar 05 2008 The inner cone has a slight circular movement but does not rotate the movement is generated by an eccentric arrangement As with the jaw crusher material travels downward between the two surfaces being progressively crushed until it is small enough to fall out through the gap between the two surfaces

Crushing blows PMV Middle East

Crushing blows PMV Middle East

Dec 10 2019 Cause analysis 1 The discharge port is blocked causing full cavity blocking 2 The Vbelt that drives the sheave to rotate is too loose causing the belt to slip 3 The eccentric shaft tightening bushing is loose causing no gap on both sides of the bearing housing of the frame so that the eccentric shaft is stuck and cannot be rotated

Why The Belt Conveyor Slipping JXSC Rock Crusher

In this article we analyze the 7 reasons for the slippage and the solutions 1 Conveyor belt tension is insufficient When the conveyor machine does not have enough tension The driving wheel and transport belt will not have enough friction between the driving force Then

Solution The surface of the drum is too smooth Adopt cast rubber roller or rubber coated roller The drum wrap angle is too small The drive roller is installed with an extended roller The tape is not tight enough Adjust the tensioning device to ensure the tension of the tape There is water or ice on the drum

Nov 01 2017 If the blade does not rotate make sure it is plugged in and the outlet has power You can unscrew the base of the blender to check for any issues If the blade still doesnt turn the problem may be the switch or the motor

Jun 08 2021 Kenmore Refrigerator Ice Dispenser Not Working How to Fix If the ice dispenser on your Kenmore refrigerator is not working here is how to troubleshoot and fix it Ice Crusher Blade Perhaps the ice crusher blades are broken bent or jammed by ice and that is why the ice dispenser is not

Kenmore Refrigerator Dispenser Problems Solved

Kenmore Refrigerator Dispenser Problems Solved

The best grape crusher

The reason why the amount of grapes does not have to be large is that turning the lever can be a tiring job even hard when adding large quantities of grapes to the vat So although it is advantageous in that it is not expensive and does not produce electricity it is disadvantageous in terms of the effort you will have to put in and the more

May 20 2021 A variety of motors and applications use gear reducers for several different reasons Just like there are various types of motors so too are there different types of specialized gear reducers making it somewhat daunting to choose the best for your application Thats why Wolters Motors amp Drives have collected some important information for you

Jul 21 2010 Most of the electric motor failures occur at the start up Most of them are caused by the overheating of motor There are also other factors which greatly affect the performance of electric motors such as low resistance dirt moisture overcurrent and vibrations Electric motors should be installed very carefully and should be looked after at regular intervals

Why Does the Rotor Rotate The reason why the rotor of an induction motor is set into rotation is as follow When the 3phase stator windings are fed by a 3phase supply then as seen from above a magnetic flux of constant magnitude but rotating at synchronous speed is set up

Screener troubleshooting Diagnosing and solving

A motor drive and motioninducing equipment such as a vibrator provide motion that helps material move through or off the screen or screens A singledeck screener moves material thats too coarse to go through a screen off the screen into a discharge outlet Material that passes through the screen is discharged separately

Screener troubleshooting Diagnosing and solving

Screener troubleshooting Diagnosing and solving

The reason why the material does not rotate with the blade is that it is subject to its weight and the friction resistance generated by the trough wall Therefore the transport of materials in the conveyor is completely a slip movement

The cone crusher is a modified gyratory crusher The essential difference is that the shorter spindle of the cone crusher is not suspended as in the gyratory but is supported in a curved universal bearing below the gyratory head or cone Figure 82 Power is transmitted from the source to the countershaft to a Vbelt or direct drive

6The vibration of cone crusher is too strong 7 The crushing cone rotates very high 8 The sudden speed of the moving cone accelerates 9 Nonuniform rotation of transmission shaft 10 Make splitting sounds 11 The coupling rotates and the crusher does not move 12 The drive shaft produces a strong knock 13 The supporting ring jumps 14

SIZE REDUCTION BY CRUSHING METHODS By

A crusher is a machine designed to reduce large rocks into smaller rocks but does not rotate the movement is generated by an eccentric arrangement crushed until it is small enough to

Dec 10 2019 The output does not meet the factory standards Cause analysis 1 The hardness or toughness of the material to be crushed exceeds the range specified in the instruction manual 2 The motor wiring position is reversed and the movable jaw rotates clockwise or the motor should have been connected in a delta connection but a star connection

Cause Analysis and Problems Solving of Jaw Crusher HXJQ

Cause Analysis and Problems Solving of Jaw Crusher HXJQ

Relevant News

Online Chat Get Quotation